ACS4000-8AL4O/E is used to control the alarm system.
Arming and disarming can be carried out through the card reader keyboard, timetable or event messages, and can also be directly linked to arming and disarming by events such as access control swiping, patrolling, and turning off lights, etc.
2 groups of completely independent industrial CAN communication BUS.
It comes with 8 defense zones that can be independently armed and disarmed, 3 universal inputs, 4 configurable relay dry contact outputs, and 4 card reader/keyboard interfaces.
All system parameters such as arming and disarming settings, timetables, linkage tables, etc. are stored in the non-volatile memory chip of the controller. Even if communication with the host is interrupted, it still works normally.
It can be linked with any module of the S6000 system to arm and disarm, and it can directly send alarm messages to the designated alarm output device on the industrial BUS to connect the CCTV system.
11-bit A/D high-precision detection of the line status of the defense zone, any defense zone supports anti-cut line and line short circuit/open circuit alarm.
DIN-Rail Mounting
Parameter Table
Model | ACS4000-8AL40/E |
Size | 144 x 90 x 63.5mm |
Communication port | 2 groups of CAN industrial BUS |
Number of defense zones | 8 defense zones that can be independently armed and disarmed |
Operation interface | 4 sets of external card reader or keyboard interface |
Local input | 11 groups of dry contact input with line detection |
Local output | 4 groups of 5A/30VDC relay output |
Installation method | DIN-Rail Mounting |
Working environment | -20~60℃,0~90%RH |
Storage environment | -40~85℃,0~90%RH |